<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-29 17-38-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 4/5, 38 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.7 kHz 86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 36 kHz 7741 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,8 dBr 1,85 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia nro 10 H-Duuri: III Menuetti (Bach JCF) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 36 kHz MIN: 13 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/29 17.37.17 Total samples: 7741 Equivalent time: 0:06:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 3,7 dBr MIN: -0,8 dBr AVE: 1,85 dBr % above 12,2 dBr: 0,0 Last value: 2,0 dBr (2026/01/29 17.37.16) 17.24 17.26 17.28 17.30 17.32 17.34 17.36 -1 0 1 2 3 4 Pm [dBr]